Save space by compact design, normally only 17.5 mm wide
Save energy and cost by avoiding unnecessary long duty periods of lighting and other electrical loads
Improve safety by warning before staircase lighting cutoff According to DIN 18015-2 the cutoff automatic for staircase lighting in apartment houses must have a warning function to prevent sudden darkness.
Possibility to extend the lighting duration by resetting capability
Steady light function, no interruption of lighting during longer work
Time switches MINITIMER | ||||||||||
Function | Output ontacts, max. | Thermal current lth [A] | Resettable | Prewarning function before time expiry | Time extension by long push button operation | Cutoff- before- capability | For flush- boxes | Depth [mm] | Width [mm] | Type |
---|---|---|---|---|---|---|---|---|---|---|
Staircase lighting time switch | 1NO | 16 | + | 55 | 17.5 | IK 8810 | ||||
Staircase lighting time switch | 1NO | 16 | + | 70 | 17.5 | RK 8810/100 | ||||
Staircase lighting time switch | 1NO | 16 | 55 | 17.5 | IK 8810/001 | |||||
Staircase lighting time switch | 1NO | 16 | 70 | 17.5 | RK 8810/001 | |||||
Staircase lighting time switch | 1NO | 16 | + | + | 55 | 17.5 | IK 8810/002 | |||
Staircase lighting time switch | 1NO | 16 | + | + | 70 | 17.5 | RK 8810/002 | |||
Staircase lighting time switch | 1NO | 16 | + | + | + | 55 | 17.5 | IK 8810/003 | ||
Staircase lighting time switch | 1NO | 16 | + | + | + | 70 | 17.5 | RK 8810/003 | ||
Staircase lighting time switch | 1NO | 16 | + | + | + | 55 | 17.5 | IK 8810/004 | ||
Staircase lighting time switch | 1NO | 16 | + | + | + | 70 | 17.5 | RK 8810/004 | ||
Fan control timer | 1NO | 16 | + | 55 | 17.5 | IK 8810/005 | ||||
Fan control timer | 1NO | 16 | + | 70 | 17.5 | RK 8810/005 | ||||
Energy saving time switch | 1NO | 16 | + | 70 | 17.5 | RK 8810/006 | ||||
Energy- | 1C/O | 10 | + | 17.5 | IK 8813 | |||||
Energy- | 1NO | 4 | + | + | 40 | OA 8823 | ||||
Light timing switch | 1NO | 10 | + | 17.5 | IK 8814 | |||||
Light timing switch | 1NO | 4 | + | + | 40 | OA 8824 | ||||
Light timing switch | 1NO | 10 | + | + | 17.5 | IK 8825 | ||||
Light timing switch | 1NO | 4 | + | + | + | 35 | OA 8825 | |||
NO = normally open contact, C/O = change over |